Specification
Click here for Voltage vs. Curent Density, Voltage vs. Power and Typical Aging Luminance chart.
|
Applied Voltage |
AC 50Vrms to AC 220Vrms
(For Split-|Electro: upto350vac) |
| Applied Frequency |
50 HZ to 3 KHZ |
Operating Temperature
(Centigrade) |
-20C ~ 50C degrees (normal) 80C(max) |
Storage Temperature
(Centigrade) |
-30 C. degree ~ 70 C. degree |
| Operating Humidity |
0% ~ 90% |
Operating Current
(100vrms/400Hz) |
1.5~P2.5 mA /sq.in |
| Capacitance |
2-5 nF/sq.in |
Brightness
(100vrm/400Hz) |
Regular brightness: 40cd/m2.
Super bright lamp: 60cd/m2
- up to 120cd/m2 |
| Thickness |
0.2~0.4mm
(min 0.19mm for 2nd Generation Foil) |
| Bend Radius |
Min.0.25"(normal foil),
(2nd generation foil can be folded but not creased.) |
| Normal Edge Seal |
0.08"(2mm) |
| Min. Edge Seal |
0.03"(0.76mm) |
| Lead Pulling |
0.5kg 10sec. |
| Lead Bending |
90 degree 250gr bending 2 times |
Soldering
Heat Resistance |
250 degree 3sec>3mm distance from EL panel with extra force applied |
| Life span up to 10,000 hours or more depending on the environment, installation, inverter/driver used, and duty cycle. |
| Environmental Test |
Temperature |
Humidity |
Test Duration |
| -20 degree |
0% |
upto168hours |
| +50 degree |
90% |
upto168Hours |
| +20 degree |
60% |
upto168Hours |
| Operating voltage and frequency - AC 100 Vrms 1 KHZ sine wave |
| StorageTest
|
Temperature |
Humidity |
Duration |
Brightness Maintainable |
| 85 degree |
|
500Hours |
75% |
| -20 degree |
|
500Hours |
75% |
| 40 degree |
90%RH |
500Hours |
75% |
| Temperature ShockTest |
-20 degree for 30min <-> 70 degree for 30min for a total of 15 cycles, with a maintained brightness of 85%. |